Measurement and automatic monitoring insulation resistance of AC/DC mixed unearthed networks

  • Anh Cam Thi Kim Hanoi University of Mining and Geology, Hanoi, Vietnam
  • Giang Truong Nguyen Hanoi University of Mining and Geology, Hanoi, Vietnam
  • Sy Tien Nguyen Hanoi University of Mining and Geology, Hanoi, Vietnam
  • Quan Van Nguyen Ministry of Science and Technology, Hanoi, Vietnam
Keywords: Automatic monitoring, Diode rectifier, Insulation resistive, Unearthed network

Abstract

Where the danger of electric shock is high, for example underground mines or medical equipment directly connected to a patient, special ungrounded power systems (unearthed networks) may be used to minimize possible leakage current to the ground. In mixed unearthed networks (AC/DC-IT) comprising alternating and direct current circuits, AC part of system is connected with DC part through rectifyer valves. Commutation of the valves causes cyclic variation of configuration of the entire galvanically connected network. A distinct feature of AC/DC-IT systems is that voltages between all points of AC side and ground may have mean value different from zero. This characteristic parameter can be used as a signal to determine fault and position to ground or decrease in insulation resistance. However, it also affects the results of the network equivalent insulation resistance measurements when a DC source is used to check insulation. The paper presents a solution to eliminate this effect and proposes a device model to measure and monitor insulation resistance. The results of this study can be applied in the design and manufacture of automatic resistance measuring and monitoring devices for AC/DC mixed unearthed networks.

References

Artemiev A.V., Vorobiev V.V, Gorscov A.A., Peretrexov V.X. (2015). Các phương pháp tự động kiểm tra điện trở cách điện mạng điện đôi có trung tính cách ly. Tạp chí Công nghệ thông minh hàng hải, số 3(29) T.1 2015 www.morintex.ru ISSN 2073-7173, tr. 128-133. (bản Tiếng Nga)

Kim Ngọc Linh (2021). Điều kiện sử dụng an toàn thiết bị bảo vệ rò điện dùng dòng đo 1 chiều trong các mạng điện mỏ hỗn hợp. Tạp chí Công nghiệp Mỏ, số 4+5+6-2021, tr. 54-58.

Olszowiec P. (2013). Application of network voltages to insulation monitoring in unearthed AC circuits with rectifiers. PAK, vol 59, 12/1013, pp.1252-1255.

Olszowiec P. (2014a). Insulation measurement and supervision in live AC and DC unearthed systems. Second edition, Springer International Publishing Switzerland, 182pp.

Olszowiec P. (2014b). Unconventional methods of analysing diode rectifiers with asymmetrical supply. Computational problems electrical engineering, vol 4, No 2, pp. 33-36.

Olszowiec P. (2016a). Modifications of diode rectifier circuits for continuous insulation measurement in live AC it networks. UDC, 621.317, pp. 43-46. DOI:10.20998/2074-272X.2016.2.08, 

Olszowiec P. (2016b). Kiểm tra cách điện của mạng có điện áp bằng các phương pháp hai  vôn kế và ba vôn kế. UDC, 621.317, tr.64-67. DOI:10.20998/2074-72X.2016.5.11, (bản tiếng Nga)

Olszowiec P. (2017). Voltages and currents in output of three - phase diode rectifiers. Riga technical university, Power and electrical engineering, 2017, vol 34, pp. 25-29.

Published
2022-04-30
Section
Applied sciences